Tuesday, December 21, 2010
【 Weak current College 】 floor heating system service life?
Heating system service life of a tube life, because you can replace the aerial parts, therefore, to warm the EAC is the key to life. Now used for floor heating systems meet the standards of tubing, design life amounts to 70 years, the actual life of more than 50 years have passed, you can think of: heating system is quite basic and building life.
Floor heating system cost?
Heating system by underground structure material selection, control system equipped with the situation.
Underground structure of the pipe, the insulation and the various affiliated material, selecting different prices vary greatly, the same selection, price differentials are generally not very large, low prices can only mean that you have selected an inferior even cannot achieve the requirements of the basic properties of materials.
Control system equipment depends on the user to achieve comfort and price/performance, to achieve different control properties, select System prices may differ by more than 100 times as many warm team did not design ability is not control system, is blind and select a single high-end product, the system does not match up to the control. The operating cost of floor radiant heating? the operating cost of floor radiant heating can generally be lower than convection heating system and 20%-40%. Now many articles on the running cost of the lack of comparability: first of all, the room where the floors, rooms facing, wall insulation, window size and whether to adopt double insulating glass so the House thermal insulation, thermal conditions vary greatly, for example single Villa faceted wall thermal direct contact with the outside world, if more insulation does not do well, the room to reach the same temperature, the quantity of heat may be doubled. Secondly, each family's habits, a different family of comfortable temperature difference between 2 to 5 degrees centigrade and family habits and evening twice-a-half-hour window for natural ventilation, the impact on operating costs. Floor heating radiant heating, heating way consistent with the human physiological demand curve, indoor temperature even lower than convection heating for 2 to 5 ° c, could make it the same warm feeling, while the floor heating temperature low temperature heat source, heat loss significantly reduce, the thermal efficiency is greatly enhanced with convection heating, which can cause the system to run costs 20 ~ 30%. If you select, use the control system properly, can not only enhance the room comfort, you can enable the system to reduce operating costs by 40% and even more.
Our community is central heating, floor heating system can be installed?. Simply install central heating home, Francis will be circulating water temperature down to the desired temperature, use of floor heating system. Different buildings in the House are generally used for heating of heat source, our system can take advantage of the existing natural gas, electricity, solar, ground source heat pumps, air source heat pump, other systems such as waste heat from the heat source. How to choose a floor heating products? to achieve good heating effect, the choice of floor heating products should follow the following principles: first, to select an experienced professional heating company. Floor heating industry has long been known as a "third product, seven characteristics of the installation", the heating system from scheme design, product selection, construction and installation to after-sales service, professional it goes without saying that if there is no professional involvement, on the one hand, affect the heating effect or result in system life greatly reduced, on the other hand will increase in the long-term use, increased use of the system energy consumption costs. Second, we must choose the products with excellent performance, high cost performance system. Floor heating is a systematic project, experienced floor heating company can according to user room structure, direction and layout of the targeted selection of high quality, cost-effective pipe, insulation, control system, which avoids the use of guerrilla shoddy work for the long-term, buried hazards can cause the system to match the price, comfort and energy saving effect. Heating system for temperature control? use temperature control system heating system for temperature control. Hop floors use partition control, usually in each floor separately set water separator, a thermostat temperature inside the region back to the water separator into the water inlet valve, regulator, and adjust the flow of floor temperature; flat layer style generally use a temperature control device, the indoor temperature feedback to the heat source, adjust the heat source water temperature; of course, different rooms feature different (master bedroom, children's room, bathroom, garage, etc.), to comfort the people requiring high temperature control will have higher requirements, this often requires the same water separator on a different circuit respectively take temperature regulation. Thermostats have a variety of, manual knob, a programmable digital LCD, feedback signal transmission can be wired or wireless transmission, not often dwelling can even remote control over the network. Bathroom floor heating can be done? of course. Bathroom with floor heating, most reflect the warm comfort, imagine a bath time feet in the bathroom, floor warm, is a more pleasant feeling. Now many bathroom floor heating buildings with traditional heating because developers in order to avoid the owners House after the destruction of the second decoration, to maintain heating system. We on the bathroom floor heating construction incorporates unique technology to not only ensure that the heating system of life, and the bathroom renovation of water and electricity, the maximum raise private space using the comfort.
Laying of floor heating, the rooms in the ground to heightening? purchase affordable housing (General storey 2.6 m clear height to 2.5 m) owners are most concerned with floor heating, the number of elevated ground. Heating system can be tailored to different ground paving materials, such as using design wood flooring, insulation and heating pipe laying the wood floor under the keel, Basic does not enhance the ground; use of floor tiles and stone, the backfill layer can be combined with floor tiles and stone paving construction, the occupier of the room height can be reduced to 2-4cm. For the purchase of commercial property owners (General-greater than 2.8 m), without considering the floor heating system in occupies the room high, simply consider different room facing, function select what ground paving material, we will give a professional design, maximum rangeDegree on increasing user comfort. What stage of the construction of the floor heating is more appropriate, duration? floor heating can all hydropower reform process, after the end of May and water decoration, strong or weak electricity system of medicine. Simple control of 120 square meters flat layer housing, floor heating construction period is 2-3 days, the backfill layer conservation period according to the season in different time required will vary; for control systems requiring high hop floors, duration will take a week or so, the backfill layer conservation period according to the season in different time required will vary. In addition, the laying of floor heating system to be very aware tube don't be subsequent repair construction damage. Floor heating pipes for underground heating will not leak, leak how to repair? floor heating are hidden underground construction, no external mechanical damage, does not leak. If the decoration, used for external damage (such as nails or ground to prevent high-temperature heat destroyed the buried pipe), should immediately contact us, our professionals will arrive, confirm the fault location and professional repair, minimize the customer's economic loss. The floor will not be hot and not hot-all or partial? we will according to the different rooms of the thermal insulation, thermal conditions, rooms feature, furniture store, shop-select flooring, heating adjustable position of the targeted for floor heating system design with no local cold or hot, coupled with a different configuration of the control system, will make the different rooms are comfortable and satisfactory temperature reached. Now many users do the floor heating is not enough for fear of the future but requires warm temperatures companies decrease the spacing pipe, many companies trying to cater to the user, causing the heating pipe laying too dense a total or partial, the room temperature is too high. If you install radiant floor heating, the ground you can choose what decoration materials now decorate market various qualified wood flooring, parquet, laminate flooring, marble, tiles, carpets, wool rugs of flax, cement, tiles, rubber flooring and floor and other decorative material can be used for floor heating. Only the thermal conductivity of different floor materials, users should be warm front tells us to choose the decoration material, so that we in heat load calculations. Floor heating to select what ground decoration material? this is not a good answer. We can only from various decorative materials for thermal conductivity of different causes of thermal efficiency differences to note, the thermal efficiency is higher, the lower the operation cost. The thermal conductivity of ground material from largest to smallest arranged in a ceramic tile: natural stone > > > parquet wood flooring, solid wood flooring > > > the pure wool rug carpet fiber. The smaller the conductivity, to achieve the same heating effect, higher operating costs. Stone, ceramic tile of thermal effects, resistance to deformation ability, is the ideal choice for geothermal heating; geothermal dedicated floor wood composite class is more suitable for heating of the material, then the indicators meets the requirements of geothermal dedicated flooring. Some good thermal stability, solid wood flooring, low moisture content, can be used for floor heating, but the General wood floor pavement to keel, geothermal heat conduction system is not easy to surface, which reduces thermal efficiency. In addition, the nail on the underground threat, need to use the special wood floor surfacing technology. Warm the selection of various composite wood flooring, wood flooring, solid wood flooring should pay attention to? General, should not be grasped to thin and thick, environmental performance, good heat resistance. We recommend that customers in the selection and use of floor coverings materials are selected during a strength of the brand, product manufacturers, it is best to choose a dedicated floor heating. In addition, the installation of floor heating special floor there is a need to be careful about is the mat, be sure to use geothermal dedicated paper mat, this mat has thermal soon, no distortion, and other characteristics, not the ordinary foam mats. Foam mat heat slowly, but the long-term effect of high temperature harmful gases under easy, endanger the health of consumers. Floor heating will not be deformed or causes harmful substances such as formaldehyde emission increase? in international standards, on the floor of the moisture, heat stability, formaldehyde emission standards have very strict requirements, absolute environmentally, the heating system of the surface temperature of 33 ° c in General, the temperature and most home indoor temperature in summer is almost no difference between, and within the Interior normal temperature range, as long as the choice in line with international standards for floor and no increase in the floor of the formaldehyde emission, have to worry about water loss and deformation.
Labels:
[:]
Subscribe to:
Post Comments (Atom)
No comments: