Indoor security tend to be neglected, in fact, the wrong way of decoration of a few accidents. Generally speaking, in the decoration engineering should note the following:
A home in a building ground not all laying marble. Marble than the floor tiles and wood flooring of weight to height out dozens of times, if the ground all pavement marble floor may make overloaded. In particular, the second layer above, because without housing security identification station identification of housing decoration, its surface decorating material weight must not exceed 40 kg/m2.
Second, for indoor decoration, not free in the load-bearing walls, punctures, demolition and doors connecting balcony and wall and to extend the original doors and Windows of the dimensions or other building doors and Windows, this would cause the building local crack and seriously affect the seismic capacity, thus shortening the life of the building.
Third, the balcony, the bathroom decoration should choose Load small material, because of excessive overload occur balcony capsizing.
4. Toilet water is also a key part in the decoration. The general practice is, in the decoration of the toilet before you plug the leak, 5 cm above the water, by tricking water test, if the water leakage, you must redo waterproof; if no leakage, but also in construction, laying the ground in careful not to undermine the waterproofing layer and tampered with water supply and heating system.
5. in the House decoration in pursuit of luxury, on the walls covered with sheet metal, ceiling mounted on two or three layers of 3-d ceiling, the decoration is not desirable. Because the walls covered with plates, occupy a large space, reduce the size of the entire space, costs are also relatively high, at the same time spent not conducive to the fire. The ceiling is too low will make the entire room have a sense of oppression.
6. Select wire to wire, jiyong aluminum wire. Due to the poor performance of Conductive aluminum wire, use wire easily fever, joint loosening or even cause a fire. Also in the construction also note that you cannot directly on the walls excavated trough buried wire should be used in formal casing installed to avoid leakage and cause a fire.
7. under construction to avoid a circular hole in the concrete drill holes, perforations, hanging ceiling, as well as installation art lighting.
8. interior decoration to guarantee gas pipeline and equipment safety requirements, not alters the pipeline, so as not to affect the normal operation of the system. In addition to electricity pipeline and equipment and gas pipeline horizontal spacing shall be not less than 10 cm, cable and gas pipe cross net distance not less than 3 cm.
9. kitchen decoration don't put gas range and placed in a wooden cabinet, nor can they be gas total valve package in the wooden cabinet. Once the Cabinet catches fire, gas valve on the fire is difficult to close, the consequences will be disastrous.