Tuesday, February 22, 2011
【 Weak current college 】 building intelligent standard specification of
Building intelligent standard specification of
Civil construction electricity design specification JGJ/T16-92
Electrical equipment installation engineering test standards for electrical equipment transfer GB50150-91
The ICAO Council "international standards and recommended practices of the annex 14--airport" "
People's Republic of China civil aviation industry standards--civil air transport airport security facility construction standards
IEEE Institute of electrical and electronics engineers-civil construction of closed-circuit television surveillance system specification
CCTR RECOMMENDATION 472-3 TV system video index
ELA-422 ELA-485 electrical specification standards
Ethernet standard IEEE 802.3 10Base-T
Ethernet standard IEEE 802.3u 100Base-T
Gigabit Ethernet standard IEEE 802.3Z
Building and campus cabling system engineering design standard GB/T50311-2000
Building and campus cabling systems engineering construction and acceptance of GB/T50312-2000
Commercial building wiring standard EIA/TIA 568A
International standard ISO/IEC 11801
Civil building cable standard EIA/TIA 586
Civil construction channel and space standards EIA/TIA 569
Civil construction communication management standard EIA/TIA 606
Civil construction communication ground standard EIA/TIA 607
Integrated services digital network primary rate interface standard data CCITT ISDN
Local telephone line engineering design specifications YDJ8-85
Urban residential and office building telephone communication facilities design standard YD/T 2008-93
City telecom network optical digital transmission system engineering design specification
Cable television broadcasting system technical specifications GY/T 106-92
Television and sound signal cable distribution system, GB/T6510-1996
Civil building cable television systems engineering technical specifications GBJ
Cable TV system engineering technical specifications GB50200-94
Cable TV system installation acceptance DB51/T 46/91
Building mine design code (2000 Edition) GB50057-94
Intelligent building design standards GB/T50314-2000
Automatic fire alarm system design specifications GB50116-98
Automatic sprinkler system installation and acceptance of GB50261-96
Construction engineering construction site for electrical safety norms GB50194-93
Electronic computer room design specification GB50174-93
Electrical equipment installation engineering bus plant construction and acceptance GBJ149-90
KV substation design specification GB50053-94
Civil engineering technical specifications of CCTV surveillance GB 50198-94
Tourist hotel in heat and air conditioning energy saving design standard GB50189-93
Halon 1301 fire-extinguishing system design specifications GB50163-92
General specification for electronic computer site GB/T2887-2000
Information technology equipment (including electrical business equipment) GB4943-1995
Electronic equipment, lightning protection guide GB/T7450-1987
Information technology equipment, radio disturbance limits and measuring methods GB9254-1998
Information processing systems-open systems interconnection network layer of the internal organizational structure of the GB/T15274-1994
Information processing system LAN GB/T15629-1995
Computer software product development documentation guide GB/T8567-1988
Computer software requirements describes the guidelines for the preparation of GB9385-88
Architectural drafting uniform standards GB/T50001-2001
Air transport airport emergency ambulance equipment GB 18040-2000
Air cargo transport terminology GB/T18041-2000
Civil airport engineering design documentation content and depth MH5016-2001
Civil Aviation public information graphic logo graphic symbols MH0005-1997
Air traffic control secondary surveillance radar equipment specification MH4010-2000
Security television monitoring burglar alarm system quality and inspection requirements DB51/T 313-2000
Build intelligent systems engineering design standard DB51/T 5019-2000
Industrial enterprise scheduling calls and Conference calls engineering design specification for CECS 36: 91
Security and protection engineering program and request GA/T 75-94
Construction supervision norms GB50319-2000
Construction project management standard GB/T50326-2001
Construction project file archive finishing standard GB/T50328-2001
Clock/logo generator General technical SJ/T10613 conditions-95
Computer software quality assurance plan standard GB/T 12504-1990
Computer software configuration management plan standard GB/T 12505-1990
Computer software category and code GB/T 13702-1992
Information technology--Open Systems Interconnection--Basic reference model--part 1: the basic model of GB/T 9387.1-1998
Information processing systems-open systems interoperabilityEven the basic reference model--part 2: security architecture for the GB/T 9387.2-1995
Information processing systems--open systems interconnection--basic reference model--part 3: naming and addressing GB/T 9387.3-1995
Information processing systems--open systems interconnection--basic reference model--part 4: management framework GB/T 9387.4-1996
Auditoria characteristics measurement method GB/T 4959-1995
Electrical Engineering CAD drawing rules GB/T 18135-2000
Conditions of contract for the construction of civil engineering (FIDIC)
Decree of 30-engineering construction projects construction tendering
Bidding Agent service fee management Softwar
The running of the Statute of a power transformer
The electricity equipment preventive test code
The electric power system protection and safety evaluation of automatic operation of the Statute of the
The electrical installation of electrical measuring instrument design code
The foreign power control components and functions of the number of
The microprocessor relay protection equipment and technical conditions "
The Exchange instrument test equipment calibration methods
The microprocessor relay protection equipment management regulations
110 ~ 500kV overhead line specification gbj233-90
1kv wiring project specification gb50258-96
35kv overhead line specification gb50173-92
EIT568 international commercial building wiring standard
EPM-voltage short-circuit current calculation procedure demonstrates
GB14308-93 foreign tourist hotel star-rating
GB50057-94 lightning protection design specification 2000 Edition
GBT50314-2000 intelligent building design standard 2000 Edition
YD5068-mobile communication base station earthing design specification
Explosion and fire hazard environment electrical specification gb50257-96
Beijing urban civil buildings near the municipal energy planning indicators description
Transformer room layout, GB 88d264-1
Cheng, Cabinet and secondary circuit specifications gb50171-92
Rural buildings design fire protection standard GBJ39 — 90
Low-voltage electrical construction and acceptance of GB 50254-96
Low-voltage electrical construction and acceptance gb50254-96
The second book communication line project budget fixed supplementary quota
Power convertor equipment construction and acceptance gb50255-96
The topic of power system interface standards
Electrical symbols meaning
Electrical lighting equipment construction and acceptance gb50259-96
Electrical professional Atlas number change
Electric equipment installation engineering construction and acceptance
Elevator electric appliance construction and acceptance gb50182-93
Elevator engineering construction quality approval standard GB50310-2002
Room air conditioner installation specification GB17790-1999
Countries and areas voltage standard
Engineering construction standard _ architectural lighting design standard .files
Industrial and civil electrical installation grounding design specifications
Industrial and civil electrical installation grounding design specifications
Blast aeration system design specifications for
Management information system of the practical guide
Thermal power plant and substation design fire protection standard gb50229-96
Agencies, organizations, enterprises and institutions to fire safety regulations (Ministry of public security Decree 61)
Construction supervision norms
Building design documentation depth requirement
Construction safety inspection standard
Mine power design specification GB50070-94
United States lightning regulations
Crane electric appliance construction and acceptance gb50256-96
Mandatory standards quiz (policy)
National survey design registered public equipment engineer temporary provisions
A commercial House decoration in place detailed rules for the implementation of the
Construction site temporary electrical safety specification JGJ46-88-7
Communications engineering quality supervision and management provisions
Small power electric motor safety requirements
Battery construction and acceptance gb50172-92
Residential design specification (provisions)
Registered electrical engineer qualification system temporary provisions
The electronic computer room construction and acceptance of SJ_T30003-93
The boiler room design code GB50041-92
The automatic fire alarm system design code GB50116-98
The construction electrical engineering construction quality approval standard "GB50303-2002
The construction electrical engineering construction quality approval standard law explains GB50303-2002
The cold storage design code GBJ 72-84
The communication with uninterrupted power supply UPS (YD-T 1095-2000)
The relay protection and technical specification for safety device (DL400-1991)
KV substation design standard GB 50053-94.
KV substation design specification
KV substation design specification
Prehospital 110kV substation unattended operation regulations for electrical equipment
3 ~ 110kV power relay device operation regulations
3 ~ 110KV voltage distribution equipment design specifications
3 ~ 110kV voltage distribution equipment design specifications 7
3 ~ 63kV AC voltage load switch
35 ~ 110kv substation design code 0007
35kV and below power cable heat shrinkable-application specification annex
35kV and below the overhead power line construction and acceptance
35KV and below the overhead power line construction and acceptance GB50173-92
66KV and following overhead power line design specification 0009
BP-2 microcomputer bus protection BP_2
D562 buildings, structures, installation of lightning protection facilities
DLT679-1999 specification for welding technology assessment
GB50116-98 automatic fire alarm system design specifications
GB50284-98 hangar fire protection design specification
JGJ91-93 scientific experimental architecture design specifications.
Explosion and fire hazard conditions electric equipment construction and acceptance GB50257-96.
Beijing city telephone Office fiber access network technical specification
Preparing electrical safety standards guide
Substation layout design techniques
Distribution, line tender documents
Transformer substation design examples
Museum of architecture and design specifications
Heating, ventilation and air-conditioning automatic control design specification
Heating, ventilation and air conditioning terminology standards (GB50155-92)
Urban roadway lighting design standard CJJ45
Urban roadway lighting design standard CJJ45-91
Cities in low voltage distribution network transformation technology guide
Rural buildings design fire protection standard
Sideband power line carrier system design guide
Low expansion foam fire-extinguishing system design specifications
Low-voltage distribution design standard GB 50054-95.
Low voltage distribution equipment and wiring design specification
Power data acquisition and control system
Underground engineering waterproof specification
Underground engineering waterproof specification provisions description
Underground architectural lighting design standards
Electrical and electronic equipment for shock protection classification GBT 2501-90.
Cable construction and acceptance
Wiring Regulations 1997
Oil-immersed power transformer, reactor, mutual inductor construction and acceptance GBJ148-90
Power transformer maintenance guide
Load control system General technical specifications
Electric power fitting glossary
Unified power system section device numbering guidelines
Electrical system voltages and reactive power technology (trial)
Power systems technical specification for dispatching automation design
Power system protection and security rules for automatic device running evaluation
The topic of power system interface standards
Power lines and substations on television stations, translator station interference protection gap standard
Electrical installation, electrical measuring instrument design specification GBJ 63-90
Electrical installations of relay protection and automation device specification
Electrical installations of relay protection and automation equipment design specifications GB50062-92
Electrical installations of relay protection and automation equipment design specifications
Electrical safety glossary GB 4776-84
Electrical relays (part 20 protection system)
Electrical peremptory norms
Electrical equipment transfer test standard GB 50150-91
Electric lighting installation and acceptance
Electrical equipment installation engineering 1kv wiring construction and acceptance GB50258 — 96
Electric equipment installation engineering of low-voltage electrical construction and acceptance GB50254 — 91
Electric equipment installation engineering of low-voltage electrical construction and acceptance GB50254 — 96
Electrical equipment installation engineering power convertor equipment construction and acceptance GB50255 — 91
Electrical equipment installation engineering power convertor equipment construction and acceptance GB50255 — 96
Electric equipment installation engineering of electrical lighting equipment construction and acceptance GB50259 — 96
Electrical equipment installation engineering high-voltage electrical construction and acceptance GBJ147-90
Electrical equipment installation engineering grounding equipment construction and acceptance GB50169 — 92
Electrical equipment installation engineering bus plant construction and acceptance GBJ149 — 90
Electrical equipment installation engineering crane electric appliance construction and acceptance GB50256 — 91
Electrical equipment installation engineering crane electric appliance construction and acceptance GB50256 — 96
Electric equipment installation engineering construction and acceptance
Electrical equipment installation engineering construction and acceptance of battery GB50172-92
Electrical equipment installation engineering construction and acceptance of rotating electrical machines GB50170-92
Electric equipment, electrical installation design specifications.
Electric equipment, electrical installation design specification 0005
Elevator installation engimeerings GBJ310-88
Electrical safety regulations (power plants and substations and electrical parts)
Electrical safety regulations (power line)
Electrical production accident investigation procedures
Electronic design specifications for computer room
Electronic computer room construction and acceptance SJT30003-93
Housing construction charting unified standard GB
Senior civil building design fire protection standard GB 50045-95
High voltage cable selection guide
High voltage overhead transmission lines and power plant and substation environment polluted areas classification and external insulation selection criteria
High voltage switch equipment of common ordering Guide
High expansion foam fire-extinguishing system design specifications
Water supply and sewerage electric installation specification
Engineering construction standard specification
Engineering construction standard design management provisions
Industrial installation engineering quality inspection and assessment of unified standards GB50252
Industrial television system engineering design specification 11
Industrial enterprise scheduling calls and Conference calls engineering design specification 21
Industrial enterprises antenna television system design specifications for 12
Industrial enterprises ' PA communication system engineering 27
Industrial enterprise communications engineering design graphics and symbols wen'an standard 22
Industrial and civil electrical installation grounding design specifications
Public entertainmentLe site fire safety regulations
Supply and distribution system design specifications
Water supply pipe specification
Features of foreign power components and its number
Foreign electrical components numbering standards
Indoor AC-voltage switch cabinet order specification
Automatic fire alarm design code for full version
Automatic fire alarm system construction and acceptance
Basic telecontrol tasks matching criteria
Measurement standard specification
Computer room with floor-technical specifications
Computer information system lightning protection specification
Computing station site security requirements
Relay protection and technical specification for safety device
The English version of relay protection
Home wiring standard TIA
Aerial insulated distribution line design specification
Aerial insulated distribution line construction and acceptance
Construction contract (demonstration text)
Construction project management specification
Construction project quality management
Construction projects in environmental protection regulations
Buildings heating sanitary and gas engineering quality inspection and assessment standards
Building electrical installation engimeerings GBJ303
Construction of water supply and sewerage and heating engineering construction quality approval standard
Construction engineering acceptance criteria GB50300-2001
Construction interior trim design fire protection standard
Building climate Division standard GB50178-93
Architecture and architectural specifications for the design of comprehensive wiring system
Building and campus cabling systems engineering construction and acceptance
Building and campus cabling systems engineering acceptance
Architectural drafting standard provisions illustrate GB
Building intelligent systems engineering management temporary provisions
AC electrical devices of over voltage and insulation coordination
AC electrical equipment grounding
AC electrical equipment grounding DLT 621 — 1997
AC high voltage circuit breaker ordering specification
Share no clearance metal oxide surge arresters
Exchange instrument test equipment calibration method SD 111-83
Exchange automatically segmented for ordering specification
Grounding equipment construction and acceptance
Import 252 (245) ~ 550kV AC high voltage circuit breakers and disconnectors technical specifications
Imported AC gapless metal oxide surge arresters technical specifications
SCR rectifier specification for operation and maintenance and repair
Static relay power line carrier dedicated transceiver specification
Static relay device specifications for inverter
Static specifications of distance protection device
Residents user household appliances damaged approach
Open system design guide
Thyristor frequency power plant operation and maintenance and repair procedures
Air conditioning and ventilation construction acceptance
Residual current operated protective devices
Green ecological residential construction main point and the technology lead then
League of popular Madden, Interbrew fire zhuanpian content
Civil engineering-circuit monitoring television specification
Civil construction electricity design specification JGJ-T 16-92
Civil building design work quota
Energy metering device management specification for 25S10
Rural electrification standards
Disc, Cabinet and secondary circuit wiring installation and acceptance of GB50171 — 92
Disc, Cabinet and secondary circuit wiring installation and acceptance
Inspection for gas relay
Gas extinguishing system construction and acceptance gb50263-97
Gas detection alarm operation maintenance rules-1
Gas detection alarm operation maintenance rules-2
Garage building design specification
National residential district intellectualization system demonstration project construction main point and the technology lead then
Civil engineering construction and acceptance GBJ134
People's air defense basement design specifications GB50038 — 94 (architecture)
People's air defense basement design specifications GB50038 — 94 (devices)
Civil engineering design fire protection standard
Three-phase AC short-circuit current calculation
Shop building design specification
A commercial House decoration in place detailed rules for the implementation of the
Shanghai standard the intelligent building design standards "
Residual current operated protective devices
10-EDM Schneider price list
11-cabinet Schneider price list
2-MCCB Schneider price list
4-ED Schneider price list
5-ENM Schneider price list
6-IC Schneider price list
7-DHM Schneider price list
8-PLC Schneider price list
9-VVD Schneider price list
Wet alarm valve performance requirements and test methods
Petrochemical enterprise design fire protection standard gb50160-92
Digital frequency relay and low frequency automatically load device specification
Transmission and distribution project startup acceptance (national standards)
Transmission and distribution project startup acceptance (national standard) 20010404
Transmission lines for communication line interference statutes
Hostels in architectural design specification
Station overvoltage protection design specification 5098
Universal electrical equipment distribution design specification
Microwave station lightning protection and earthing design standard YD 2011-93
Relay protection equipment operational management procedures
Sanitaryware installation height
Lines, equipment bidding documents
Small oil storage depots and petrol station design specification
Compressed air station design specification GBJ29-90.
Hospital wastewater treatment design specification
Mobile communication base station design specification for lightning protection and grounding YD 5068-98
Used to measure DC high voltage bar-bar clearance
Cable TV system engineering technical specifications
On-load tap-changer run repair Guide
Crude oil and natural gas engineering design fire protection standard
Telecontrol equipment and systems terms
TelecontrolEquipment and systems-part 1: General principles, paragraph 2: the norm of guide
Telecontrol equipment and systems work conditions, environmental conditions and power
Telecontrol equipment and systems interface (electrical characteristics)
Telecontrol equipment and systems terms
Remote Terminal General technical specifications
Intelligent building design standard.
Short-wave broadcasting transmitters in, and the cable carrier systems of protection gap standard
People's Republic of China national standard specification for low-voltage distribution design
People's Republic of China national standard Cleanroom design specification GBJ73
Metrology law People's Republic of China
People's Republic of China home decoration project quality specifications
People's Republic of China bidding law
Periodic and related phenomena of quantities and units
Residential design specification (GB 50096-1999)
Decoration engineering construction and acceptance GBJ210
Handling oil terminal fire design specification
Elevator installation engimeerings GBJ310-88
Industrial furnaces engimeerings GB 50309-92
Ventilation and air conditioning engimeerings GBJ304-88
Precast concrete component quality inspection and evaluation standards GBJ321-90
Building electrical installation engimeerings GBJ303 — 88
Buildings heating sanitary and gas engimeerings GBJ302 — 88
Construction and installation the project quality inspection and assessment of unified standards GBJ300 — 88
Electric equipment installation engineering of electrical lighting equipment construction and acceptance GB50259 — 96
Electrical equipment installation engineering 1kv wiring construction and acceptance GB50258 — 96
Architectural engineering quality inspection and evaluation standards GBJ301 — 88
Electrical equipment installation engineering crane electric appliance construction and acceptance GB50256 — 96
Electrical equipment installation engineering power convertor equipment construction and acceptance GB50255 — 96
Electrical equipment installation engineering explosion and fire hazard conditions electric equipment construction and acceptance GB50257 — 96
Electric equipment installation engineering of low-voltage electrical construction and acceptance GB50254 — 96
Industrial installation engineering quality inspection and assessment of unified standards GB50252-94
Project Visual construction site welding inspection specification CECS71: 94
Ventilation and air-conditioning engineering construction and acceptance GBJ243-82
Concrete pumping construction technology for JGJ/T10 — 95
Housing construction workers technical level standard CJJ26--89
Civilian housing repair project construction for CJJ/T53-93
Decoration engineering construction and acceptance GBJ210-83
Wood frame construction and acceptance GBJ206-83
Steel structure project construction and acceptance GB50205-95
Concrete structure project construction and acceptance GB50204-92
Masonry construction and acceptance GBJ203-83
Testing method for welded joint of steel bars JGJ27-86
Spherical tank construction and acceptance GBJ94-86
Portland cement concrete pavement construction and acceptance GBJ97-87
Concrete strength testing and evaluation standards GBJ107-87
Hydraulic slide formworks GBJ113-87
Concrete admixtures specification GBJ119-88
Soil test method standards GBJ123-88
Industrial equipment and piping heat insulation construction and acceptance GBJ126 — 89
Vertical cylindrical steel welded tank construction and acceptance GBJ128-90
Civil engineering construction and acceptance GBJ134-90
Water supply and drainage structures construction acceptance GBJ141-90
Electrical equipment installation engineering high-voltage electrical construction and acceptance GBJ147-90
Electric equipment installation engineering, oil-immersed power transformer, reactor, mutual inductor construction and acceptance GBJ148-90
Electrical equipment installation engineering bus plant construction and acceptance GBJ149-90
Ancient wooden structure maintenance and reinforcement technology standard GB50165-92
Cable construction and acceptance GB50168-92
Electrical equipment installation engineering grounding equipment construction and acceptance GB50169-92
Electrical equipment installation engineering construction and acceptance of rotating electrical machines GB50170-92
Electrical equipment installation engineering, Cabinet and secondary circuit wiring installation and acceptance of GB50171-92
Electrical equipment installation engineering construction and acceptance of battery GB50172-92
Open pit mine construction and acceptance GB50175-93
Electrical equipment installation engineering kV overhead power line construction and acceptance GB50173-92 industrial metal pipe engimeerings GB50184-93
Construction engineering construction site for electrical safety norms GB50194-93
Industrial equipment and pipe insulation engimeerings GB50185-93
Earth-moving and blasting engineering construction and acceptance GBJ201-83
Ground and foundation engineering construction and acceptance GBJ202-83
Asphalt pavement construction and acceptance GBJ92-86
Ordinary concrete long-term performance and durability test method for GBJ82-85
Common test methods of mechanical properties of concrete GBJ81-85
Ordinary concrete mix performance test method GBJ80-85
Underground waterproof construction and acceptance GBJ208-83
Building ground engineering construction and acceptance GB50209-95
Engineering measurement specification GB50026-93
Industrial furnaces for construction and acceptance GBJ211-87
Building anticorrosion construction and acceptance GB50212-81
Mine shaft construction and acceptance GBJ213-90
Composite steel template specification GBJ214-89
Engineering survey basic terminology standard GB50228-96
Construction and installation the engimeerings TJ305-75
Mechanical equipment installation and acceptance of TJ231 (2)-78 volume 2 install metal cutting machine tools
Mechanical equipment installation and acceptance of TJ231 (3)-78 third album mechanical presses, air hammers hydraulic press, foundry equipment installation
Mechanical equipment installation and acceptance of TJ231 (4)-78 fourth album from hygiene equipment, elevators, continuous transportation equipment installation
Mechanical equipment installation and acceptance of TJ231 (5)-78 fifth book of the compressor, fan, pump, air separation equipment installation
Mechanical equipment installation and acceptance of TJ231 (6)-78 part VI crushing grinding equipment, winches, stationary diesel engines, industrial boiler installation
Mechanical equipment installation and acceptance Universal standardized GB50231-98
Construction and installation the engimeerings TJ306-77
Construction and installation the engimeerings TJ306-77 container project
Construction and installation the project quality inspection and evaluation standards TJ307-77 industry pipeline installation engineering
110 ~ 500KV overhead power line construction and acceptance GBJ233-90
Industrial pipe construction and acceptance GBJ235-82
On-site equipment, industrial pipeline welding engineering construction and acceptance GBJ236-82
Heating and sanitary engineering construction and acceptance GBJ242-82
Architectural lighting design standard GB/T 50033--2001
Cinder lime class road base construction interim specifications CJJ5-83
Municipal engineering, construction, maintenance and technical level of sewage treatment workers — standard CJJ18 88
Urban garden workers technical level standard CJJ20-89
Ancient building construction workers technical level standard CJJ21-89
Urban public transport workers technical level standard CJJ22-89
The urban water sector workers technical level standard CJJ23-89
Town gas, thermal workers technology level standard CJJ24-89
Steel slag and lime class road base construction and acceptance CJJ35-90
Urban road maintenance technical specification CJJ36-90
Emulsified asphalt pavement construction and acceptance CJJ42 — 91
Hot mix asphalt pavement recycling construction and acceptance CJJ43-91
Urban road embankment construction and acceptance CJJ44-91
Town gas pipeline repair and maintenance of the technical specification for CJJ51-92
Sanitation workers technical level standard CJJ25-89
Flexible pavement design parameters measurement standard CJJ/T59-94
Technical specification for housing leakage CJJ62-95
Pavement slurry seal housing construction for CJJ66-95
Underground water supply steel pipe cement mortar lining technology standard CECS10: 89
Import of timber in the engineering application of provisions on CECS12: 89
Outdoor hard PVC pipe construction and acceptance CECS18: 90
Industrial furnace cement castable winter construction technology for CECS27: 90
Technical specification for concrete tower construction CECS58: 94
Construction and installation engineering metal melting weld radiography structure measuring standard CECS70: 94
Steel welded and acceptance JGJ18-84
Tower mast steel structure construction and acceptance CECS80: 96
Industrial automation and instrumentation engineering construction and acceptance GBJ93-86
Construction machinery technical specification for using security JGJ33-86
Construction machinery technical test procedures JGJ34-86
Construction site temporary electrical safety specification JGJ46-88
Soil quality with gravel or pebbles standard and checking ways JGJ53-92
Ordinary concrete mix design for JGJ/T55-96
Concrete water-quality standards and test methods JGJ56-84
Construction safety check scoring criteria JGJ59-88
Concrete mixing water standard JGJ63-89
Hydraulic slide template construction safety code JGJ65-89
PY-drill-pressuremeter test procedures JGJ69-90
Mortar basic performance test method JGJ70-90
Clean room construction and acceptance JGJ71-90
Architectural decoration engineering construction and acceptance JGJ73-91
Truss engimeerings JGJ78-91
Building Foundation technology specification JGJ79-91
Construction heights Security specification JGJ80-91
Construction steel structure welding code JGJ81-91
Steel structure of high strength bolted connections of the design, construction and acceptance JGJ82-91
Masonry mortar mix design procedure JGJ/T98-96
Mechanical spray plaster construction for JGJ/T105-96
Technical specification for engineering network plan JGJ/T1001-91
Extra fine sand concrete preparation and application of procedures BJG19-65
Housing construction charting unified standard GB/T 50001 — 2001 provisions description
Housing construction charting unified standard GB/T 50001 — 2001
Architectural modulus harmonized standard GBJ2-86
Technical specification for pump isolation CECS59: 94
Plant construction standard modular coordination GBJ6-86
Industrial enterprises in the design specification for standard gauge railway GBJ12-87
Architectural design fire protection standard (revised edition) GBJ16-87
Mine road design specifications GBJ22-87
Compressed air station design specification GBJ29-90
Oxygen station design specification GB50030-91
Acetylene station design specification GB50031-91
Industrial enterprises lighting design standard GB50033-91
Industrial enterprises lighting design standard GB50034-92
Industrial enterprises in the design of health standards TJ36-79
Code for design of building ground GB50037-96
People's air defense basement design specifications GB50038-94
Rural buildings design fire protection standard GBJ39-90
Boiler room design specification GB50041-92
Senior civil building design fire protection standard (2001 Edition) provisions illustrate GB50045-95
Senior civil building design fire protection standard GB50045-95
Building stairs modular coordination standard GBJ101-87
Industrial building anti-corrosion design specifications GB50046-95
Reverberation room method for sound absorption coefficient measurement specification GBJ47-83
Code for design of miniature thermal power plant GB50049-94
Residential design specification GB50096-1999
Garage design fire protection standard (trial) GBJ67-84
Small hydroelectric power station design specification GBJ71-84 (trial)
Cold storage design specification GBJ72-84
Cleanroom design specification GBJ73-84
Petroleum library design specification GBJ74-84
Architectural acoustic measurement specification GBJ75-84
Reverberation time measurement specification GBJ76-84
Automatic sprinkler system design specifications section describes GBJ50084-2001
Automatic sprinkler system design specifications GB50084-2001
Port terminal building design standard JGJ86-92
Industrial noise control design specification GBJ87-85
Standing wave tube sound absorption coefficient and impedance ratio measurement specification GBJ88-85
Civil explosives factory design safety specifications GBJ89-85
Railway stations and terminals design specification GBJ91-85
Residential building design specification GBJ96-86
Civil engineering design fire protection standard GB50098-98
Primary architectural design specification GBJ99-86
Residential building modular coordination standard GB/T 50100-2001
Residential building modular coordination standard provisions illustrate GB/T 50100-2001
The total figure drawing standards GB/T50103-2001
The total figure drawing standards provisions illustrate GB/T50103-2001
Architectural drafting standards GB/T50104-2001
Architectural drafting standard provisions illustrate GB/T50104-2001
Scientific experimental architecture design specification JGJ91-93
Halon 1211 fire-extinguishing system design specifications GBJ110-87
Water supply and drainage drawing standards GB/T50106-2001
Water supply and drainage drafting standard provisions illustrate GB/T50106-2001
Underground engineering waterproof specification GB 50108-2001
Underground engineering waterproof specification provisions illustrate GB 50108-2001
Office building design standard JGJ67-89
Heating, ventilation and air conditioning drawing standards GBJ114 — 88
Automatic fire alarm system design specifications GBJ116-88
Civil Code for design of building sound insulation GBJ118-88
Criteria for the evaluation of building sound insulation GBJ121-88
Industrial noise measurement specification GBJ122-88
Civil construction lighting design standard GBJ133-90
Urban land-use planning and land use classification and standards GBJ137-90
Construction of fire extinguishers configuration design specification GBJ140-90
Museum of architecture and design specification JGJ66-91
Underground and the Earth poudres warehouse design safety specifications GB50154-92
Small oil storage depots and petrol station design specification GB50156-92
Subway design specification GB50157-92
Petrochemical enterprise design fire protection standard GB50160-92
Fireworks factory design safety specifications GB50161-92
Road engineering drawing standards GB50162-92
Halon 1301 fire-extinguishing system design specifications GB50163-92
Engineering Photogrammetry specification GB50167-92
Electronic computer room design specification GB50174-93
Civil building thermal design specification GB50176-93
Hydrogen-oxygen station design specification GB50177-93R > building climate Division standard GB50178-93
Rivers flow test specification GB50179-92
Urban residential district plan design standard GB50180-93
Crude oil and natural gas engineering design fire protection standard GB50183-93
Industrial enterprises in total graphic design specifications GB50187-93
Villange GB50188-93
Tourist hotel in heat and air conditioning energy saving design standard GB50189-93
Carbon dioxide fire extinguishing system design specifications GB50193-93
Producer gas station design specification GB50195-94
High expansion, expansion foam extinguishing system design specifications GB50196-93
Open pit mine engineering design specifications GB50197-94
Coal industry standard mine design GB50215-94
Water spraying fire-extinguishing system design specifications GB50219-95
Urban traffic plan design standard GB50220-95
Construction interior trim design fire protection standard GB50222-95
Building anti-corrosion engimeerings GB50224-95
Railway passenger station building design standard GB50226-95
Thermal power plant and substation design fire protection standard GB50229-95
Urban planning and design of public toilet standard GJJ14-87
Urban public transport station, farm, factory design specification CJJ15 — 87
Municipal solid waste landfill technology standard GJJ17-88
Urban sanitation facilities set standard GJJ27-89
Urban roadway lighting design standard GJJ45-91
Urban land use classification code GJJ46-91
Design specification for municipal solid waste transfer station GJJ47-91
Park design specification GJJ48-92
Metro stray current corrosion protection technology for CJJ49-92
Urban flood control project design specification CJJ50-92
Municipal solid waste composting in aerobic static specification CJJ/T52-93
Soft felt roof waterproofing technology for GECS29: 91
Workshop GRP daylighting design standard CECS44: 92
Enhanced CPE rubber membrane waterproofing technology for CECS63: 94
Civil building design for thermal Engineering (trial) JGJ24-86
Archives design standards (for trial implementation) JGJ25-86
Civil building energy-saving design standards (existing building) (trial) JGJ26-86
Building standard meteorological parameters JGJ35-87
Hostels in architectural design specification JGJ36-87
Civil building design general clauses (trial) JGJ37-87
Library building design standards (for trial implementation) JGJ38-87
Nurseries, kindergartens architectural design specification JGJ39-87
The Museum of architecture and design specification JGJ41-87
Residential building technical and economic evaluation standard JGJ47-88
Shop building design standard JGJ48-88 (trial)
General Hospital design specification JGJ49-88
Disabled use of urban roads and constructions (trial) JGJ50-88
Theatre building design standards (for trial implementation) JGJ57-88
Cinema building design standard JGJ58-88
The hotel building design standard JGJ62-90
Outdoor water design specification GBJ13-86
Outdoor drainage design specification GBJ14-87
Construction of water supply and drainage design specification GBJ15-88
Heating, ventilation and air conditioning design specification GBJ19-87
Water hydrology geolo GBJ27-88
Town gas design specification GBJ50028-93
Industrial enterprise communication design specification GBJ42-81
Hospital discharge standard GBJ48-83
Industrial cooling water treatment design specification GB50050 — 95
Supply and distribution system design specifications GB50052-92
KV substation design specification GB50053-94
Low-voltage distribution design specification GB50054-95
Universal electrical equipment distribution design specification GB50055-93
Electric equipment, electrical installation design specification GB50056-93
Building mine design specification GB50057-94
Explosion and fire hazard environment design specification GB50058-92
35 ~ 110kv substation design specification GB50059-92
3 ~ 110KV voltage distribution equipment design specifications GB50060-92
Industrial and civil 35 kV and below the overhead power line design specification GBJ61-83
Electrical installations of relay protection and automation equipment design specifications GB50062-92
Electrical installation, electrical measuring instrument design specification GBJ63-90
Industrial and civil electric appliance overvoltage protection design specification GBJ64-83
Industrial and civil electrical installation grounding design specifications GBJ65-83
Refrigeration equipment installation and acceptance of GBJ66-84
Water supply and drainage engineering structure design code GBJ69-84
Mine power design specification GB50070-94
Chimney construction and acceptance GBJ78-85
Industrial enterprise communications grounding design specifications GBJ79-85
Industrial circulating water cooling design specification GBJ102-87
Industrial water softening desalination design specification GBJ109-87
Industrial television system engineering design specifications GBJ115-87
Industrial enterprises antenna television system design specifications GBJ120-88
Water supply and drainage design basic terminology standard GBJ125-89
Automatic instrument installation engimeerings GBJ131-90
Water level observations standard GBJ138-90 inland navigation standard GBJ139-90
Short-wave broadcasting transmitters in, and the cable carrier systems of protection gap standard GBJ142-90
Overhead power lines and substations on TV and retransmitting radio interference protection spacing standard GBJ143-90
Electrical equipment installation engineering test standards for electrical equipment transfer GB50150-91
Low expansion foam fire-extinguishing system design specifications to GB50151-92
Heating, ventilation and air conditioning terminology standard GB50155-92
Rivers of sediment test specification GB50159-94
Civil engineering-circuit monitoring television specification GB50198-94
Hydraulic engineering reliability design statistical standards GB50199-94
Cable TV system engineering technical specifications GB50200-94
Flood control standard GB50201 — 94
Code for design of electric power engineering cable GB50217-94
Shunt capacitor installation design specification GB50227-95
Sewer maintenance safety technical specification CJJ6-85
Residential gas water heater installation acceptance CJJ12-86
Urban heating network construction and acceptance CJJ28 — 89
PVC-u drainage pipe design for CJJ29-89
PVC-u drainage pipe construction and acceptance CJJ30-89
Urban sewage treatment plant subsidiary buildings and ancillary equipment design standard CJJ31-89
Including bath water water treatment design specification CJJ32-89
City gas transmission and distribution construction and acceptance CJJ33-89
Urban heating network design specification CJJ34-90
High turbidity water water supply design specification CJJ40-89
Town waterworks subsidiary buildings and ancillary equipment design standard CJJ41-91
Code for design of wastewater stabilization ponds CJJ/T54-93
Heating terminology standard CJJ55-93
Urban sewage treatment plant operation, maintenance and security technical specification CJJ60 — 94
Urban underground pipeline detection technology for CJJ61 — 94
Polyethylene gas pipeline engineering technical specification CJJ63-95
Urban waste treatment plant (field) design specification CJJ64-95
Environmental health terminology standards CJJ65-95
Coking plants, coal gasification plant phenolic wastewater treatment design specification CECS05: 88
Hospital wastewater treatment design specification CECS07: 88
Industrial enterprises and control user-machine engineering design specifications CECS09: 89
Outdoor hard PVC pipe engineering design practice for CECS17: 90
Concrete sewer project closed gas inspection standards CECS19: 90
Architectural design specifications in the Shui CECS30: 91
Shunt capacitor series reactor design selection criteria CECS32: 91
Shunt capacitor voltage, capacity range selection criteria CECS33: 91
Water supply hydro-geological survey and remote sensing technology for CECS34: 91
Industrial enterprise scheduling calls and Conference calls engineering design specifications CECS36: 91
Industrial enterprise communications engineering design graphics and text symbol standard CECS37: 91
Specifications for the design of deep aeration CECS42: 92
Underground architectural lighting design standard CECS45: 92
Design specification for drinking water fluoride CECS46: 93
Sand, stone alkali reactive rapid test method CECS48: 93
Filter design for air-water washing CECS50: 93
Indoor lamps light distribution category and lighting design parameter standard CECS56: 94
Residential community water supply and drainage design specification CECS57: 94
Half that is hot-water heater for hot water supply design specification for CECS60: 94
Water reuse design specification CECS61: 94
Industrial enterprises ' PA communication system engineering design specifications CECS62: 94
AC high voltage overhead power transmission lines radio interference effect on navigation specification for calculation of CECS64: 94
Transmission line on dual-line telephone line interference calculations for CECS65: 94
AC high voltage overhead transmission lines on shortwave radio direction-finding station (station) and the delivery station (station) protection specification for calculation of space: 94 CECS66
AC Electric Railway on telecommunication line noise interference calculations for CECS67: 94
Construction and architectural complex of GCs design specification CECS72: 95
Belt filter sewage sludge dewatering design specification CECS75: 95
Pressure water system design specifications CECS76: 96
Special single stack drainage system design specifications for CECS79: 96
Rural water supply design specification CECS82: 96
Civil construction electricity design specification JGJ/T16-92
Diet building design standard JGJ64-89
Geotechnical Engineering investigation specification provisions illustrate GB 50021 2001
Geotechnical Engineering investigation standard GB 50021 2001
Structural load code provisions illustrate GB 50009 — 2001
Structural load code GB 50009 — 2001
Building a unified standard for reliability design GB 50068-2001
Construction engineering geological drilling technology standard JGJ87-92
Anti-seismic design code GB50011-2001
Construction earthquake resistance design specification provisions illustrate GB50011-2001
Masonry structure design code GBJ3-88
Wood design specification GBJ5-88
Code for design of building Foundation GBJ7-89
Prestressed reinforcement anchors, fixture and connector application technical specification JGJ85-92
Concrete structure design code GBJ10-89
Steel structure design code GBJ17-88
Cold-formed steel structure technical specification GBJ18-87
Soft soil engineering geolo JGJ83-91
Seismic qualification standards GB50023-95
Collapsible loess building code GBJ25-90
Outdoor water supply and sewerage and gas and heating engineering seismic design code TJ32-78 (the trial)
Dynamic machine Foundation design specification GB50040-96
Outdoor water supply and drainage facilities in seismic evaluation standards (for trial implementation) GBJ43-82
Outdoor gas seismic evaluation of thermal power engineering facilities standards (for trial implementation) GBJ44-82
Chimney design specification GBJ51-83
Building structural design standard (trial) GBJ68-84
Code for design of reinforced concrete silo GBJ77-85
Building structural design universal symbols, units and basic terminology GBJ83-85
Sprinkler irrigation engineering technical specifications GBJ85-85
Bolt shotcrete technique specification GBJ86-86
Architecture cartography standards GB/T50105-2001
Architecture cartography standards provisions illustrate GB/T50105-2001
Building geotechnical engineering investigation basic terminology standard JGJ84-92
Seismic design standards for railway engineering GBJ111-87
Expansive soil building technical specifications GBJ112-87
Anti-seismic evaluation of industrial structure standard GBJ117-88
Road construction terminology standard GBJ124-88
Aerial ropeway engineering technical specifications GBJ127-89
Masonry basic mechanics performance test method standards GBJ129-90
RC l-plate structure specification GBJ130-90
Engineering structure design basic terminology and general character GBJ132-90
Towering structure design code GBJ135-90
Industrial plant reliability qualification standards GBJ144-90
Soil classification standard GBJ145-90
Fly ash concrete application specification GBJ146-90
Concrete structure test method standards GB50152-92
Engineering structural reliability design of unified standards GB50153-92
Port project a unified standard for reliability design GB50158-92
Concrete quality control standard GB50164-92
Flood engineering technical specifications GB50181-93
Port project basic terminology standard GB50186-93
Multi-storey building floor code for design of microvibration earthquake GB50190-93
Structure seismic design code GB50191-93
Tugs on the engineering design specifications GB50192-93
Technical specification of the roofing project GB50207-94
Railway engineering reliability design of unified standards GB50216-94
Rock mass classification standard GB50218-94
Municipal Road engimeerings CJJ1-90
Municipal bridge engineering quality inspection and assessment of standard CJJ2-90
Municipal sewerage engimeerings CJJ3-90
Fly ash lime class road base construction interim specifications CJJ4 — 83
Urban Exploration Geophysics specification CJJ7-85
Urban measurement specification CJJ8-85
Municipal engineering quality inspection and evaluation standards (flood) CJJ9-85
Water supply tube design, construction and acceptance CJJ10-86
City bridge design guidelines CJJ11-93
Water supply hydro-geological drilling and sinking practice CJJ13-87
The urban water hydrology geolo CJJ16-88
Urban exploration, surveying workers technical level standard CJJ19-89
Urban road design standard CJJ37-90
Urban heating network engimeerings CJJ38-90
Ancient building construction engineering quality inspection and evaluation standards (northeast) CJJ39-91
Municipal engineering exploration specification CJJ56-94
Urban planning project in geolo CJJ57-94
Ultrasonic rebound testing technical specification for concrete strength CECS02: 88
Drilling method testing technical specification for concrete strength CECS03: 88
CPT technology standard CECS04: 88
Grid, grid flocculator design standard CECS06: 88
Brick silo technology specification CECS08: 09
Test method of steel fiber reinforced concrete CECS13: 89
Swimming pool water supply and drainage design specification CECS14: 89
Buried hair oil gas steel pipe structure design code CECS15: 90
Prestressed concrete pipes structure design code CECS16: 90
Brick masonry structure design and construction of statutes CECS20: 90
Ultrasonic testing technical specification for concrete flaws GECS21: 90
Anchorage design and construction specifications CECS22: 90
Steel rack structure design code CECS23: 90
Fire retardant coatings for steel structures specification application CECS24: 90
Concrete structure reinforcement technology standard CECS25: 90
Double reinforced concrete structure design and construction of statutes CECS26: 90
Tubular structure design and construction of statutes CECS28: 90
Steel cable tray engineering design specifications CECS31: 91
Hammer penetration method for CECS35: 91
Steel fiber reinforced concrete structure design and construction of statutes CECS38: 92
Design of RC deep beam: 92 statutes CECS39
Concrete and precast concrete component quality control procedure CECS40: 92
PVC pipe for water supply in building design and construction of acceptance CECS41: 92
Precast reinforced concrete beam-column joints and connections design specification for CECS43: 92
Continuous beams and reinforced concrete frame considering design specification for redistribution CECS51: 93
Whole prestressing force technical specification for slab-column structures CECS52: 93
Concrete base content limit for standard CECS53: 93
Pocket penetrometer CECS54: 93
Pore-water pressure measurement procedures CECS55: 93
Sodium hydroxide (lye) reinforcement of collapsible code CECS68: 94
After loading allocation method for testing technical specification for concrete strength CECS69: 94
Venue technical specification for micro-vibration measurement CECS74: 95
Steel reinforcement technology standard CECS77: 96
Brick plus layer specification CECS78: 96
Pipeline engineering structure commonly used terminology CECS83: 96
Industrial building wall plate design and construction rules (trial) JGJ2-79
Industrial and civil construction and pile foundation design and construction rules JGJ4 — 80
Medium-sized block building design and construction of statutes JGJ5-80
High-rise building box Foundation design and construction of statutes JGJ6-80
Grid structure design and construction of statutes JGJ7-91
Reinforced lightweight concrete structure design code for JGJ12-82
Reinforced concrete structure column multilayer brick masonry techniques JGJ/T13-94
Concrete hollow block building technical specification JGJ/T14-95
Early test method for compressive strength of concrete JGJ15-83
Cold call wire prestressed concrete structure design and construction of statutes JGJ19-92
Large template multistory structure design and construction of statutes JGJ20-84
V-shaped folding roof design and construction of statutes, JGJ/T21-93
Rebound method technical specification for concrete compressive strength JGJ/T23-92
Fly ash for concrete and mortar applied technology for JGJ28-86
Lightweight concrete technical specification JGJ51-90
Ordinary concrete sand quality standard and checking ways JGJ52-92
Calcium lignosulfonate superplasticizer in concrete technical rules in use JGJ54-79
Brick (KP1) seismic design and construction of statutes JGJ68-90
High-rise building geotechnical engineering investigation procedures JGJ72-90
People's Republic of China construction law 1999
Indoor decoration management approach
The tall buildings design fire protection standard of partial amendments
The architectural design of the fire code 2001 sent for approval
DBJ01-601-99 Beijing residential telecommunications facilities design specifications
GB50156-92 small petroleum storage depots and petrol station design specification
JGJ91-93 scientific experimental architecture design specification
Low-voltage distribution design specification
Underground engineering waterproof specification
The sixth article in seismic design
Electrical installations of relay protection and automation devices
Waterproof concrete construction craft standard
Housing construction area including which
Housing construction charting unified standard G1
Housing construction charting unified standard G2
Housing construction charting unified standard GB
Senior civil building design fire protection standard GB 50045-95
Water supply and sewerage electric installation specification
Engineering construction standard specification
National Development Planning Commission, releases the primary architectural design standard "
National building standard design Atlas Gaihao checklist
Home frequently asked questions FAQ
Construction project management specification
Architectural drafting standard GB
Architectural drafting standard provisions description
Bare conductor insulated conductors and color flag GB 7947
Feasibility study report preparation, filing, examination and approval
Civil construction electricity design specification JGJ-T 16-92
Civil engineering construction and acceptance GBJ134
People's air defense basement design specifications GB50038 — 94 (architecture)
A commercial House decoration in place detailed rules for the implementation of the
Sanitaryware installation height
Project proposal preparation, filing, examination and approval
For Sudan oilfield firefighting system materials and equipment for inspection and installation
People's Republic of China Law of Corporation
Residential design specification
Indoor decoration management approach
ISO9000-14000 standard greatly entire
Power cable fault detection technology
Control system for computer-aided engineering software CAE2000
Three-phase AC short-circuit current calculation
The cold storage design code GBJ 72-84.
DLT679-1999 specification for welding technology assessment
The installation work construction organization plan
Load control system General technical specifications
Project Visual construction site welding inspection specification CECS71: 94
Engineering design fees 2002 Edition
Industrial installation engineering quality inspection and assessment of unified standards GB50252
Industrial automation and instrumentation engineering construction and acceptance
State-building standards
Domestic and foreign common standards and codes
Measurement standard specification
Civil building design work quota
HVAC specification
Shop building design specification
Shanghai standard the intelligent building design standards "
People's Republic of China power law
Metrology law People's Republic of China
Periodic and related phenomena of quantities and units
Decoration engineering construction and acceptance GBJ210
Heating, ventilation and air-conditioning automatic control design specification
Heating, ventilation and air conditioning terminology standards (GB50155-92)
Water supply and drainage drafting standard GB
Water supply pipe specification
The national design specification GBJ73 clean workshop
Buildings heating sanitary and gas engineering quality inspection and assessment standards
Construction of water supply and sewerage and heating engineering construction quality approval standard
Water-saving apparatus construction industry standard implemented on 1 October
Air conditioning and ventilation construction acceptance
Outdoor water design specification GBJ13 — 86
Outdoor drainage design specification GBJ14 — 87
Ventilation and air-conditioning engineering construction and acceptance GBJ243-82
Hospital wastewater treatment design specification
The water supply and drainage drafting standards GB50106-2001
The automatic sprinkler system design code 2001 Edition provisions description
The architectural design of the fire code 2001 sent for approval
GB50116-98 automatic fire alarm system design specifications
JGJ91-93 scientific experimental architecture design specification
Rural buildings design fire protection standard
One-way valve performance requirements and test methods
Low expansion foam fire-extinguishing system design specifications
Point-type heat fire detectors
Point of the type smoke detector
Point infrared flame detector
Elevator floor door fire resistance test methods
Carbon dioxide fire extinguishing system design specifications
Fireproof glass non-bearing wall General technical specifications
Fire doors with door closer test method
General specifications of extinguishing
Fire retardant coatings for steel structures general specifications
Steel fire shutter General technical specifications
Steel fire doors General technical specifications
High expansion foam fire-extinguishing system design specifications
Public entertainment fire safety regulations
Fixed fire-extinguishing system drive, control equipment General technical specifications
Fire alarm Controller General technical specifications
Automatic fire alarm system construction and acceptance
Construction interior trim design fire protection standard
Architectural design fire protection standard GBJ16 — 87 (revised edition)
Combustible gas detector CD15322 — 94
Ammonium phosphate powder extinguishing agent
Fire extinguisher maintenance and scrap
Wooden fire door General technical specifications
Gas extinguishing system construction and acceptance gb50263-97
Garage, garage, parking design fire protection standard
Driven valve performance requirements and test methods
Civil engineering design fire protection standard
Sprinkle of technical requirements and test methods
Shanghai local fire design specification of the characteristics
Wet alarm valve performance requirements and test methods
Indoor hydrant instead of GB 3445-82
Manual fire alarm button on technical requirements and test methods
Portable fire extinguisher inspection rules
Flow indicators of performance requirements and test methods
Water fog sprinkler performance requirements and test methods
Sodium bicarbonate powder extinguishing agent quality grading
Linear beam point-smoke detector
Fire safety belt
Fire safety signs
Fire management system software
Fire-pressure water sharing equipment performance requirements and test methods
Fire pump adapter, fire received production enterprise measurement detection apparatus equipped with specification
Fire pump adapter instead of GB 3446-82
Fire emergency lighting General technical specifications
Fire use wireless telephone technology requirements and test methods
Pressure switch for fire performance requirements and test methods
Small oil storage depots and petrol station design specification
Select valve performance requirements and test methods
Handling oil terminal fire setMeter specifications
【 Weak current College 】 detection method for intelligent building system
Intelligent building using advanced computer technology, control technology, communication technology, as users and managers provides the control functions, data processing, display the operation set, run the secure and reliable construction equipment automation systems (Building Automation System called BA system). BA system uses a distributed control technology for construction equipment to conduct a comprehensive, real-time monitoring, improving the quality of building equipment, reducing the management workload, reduce energy consumption in buildings, in building intelligent systems in which an important role. However, the long-term quality of systems engineering in China has not BA, BA of normal operational system, which is mainly due to the detection of BA systems engineering and acceptance has not yet been established on the basis of the science.
Over the past three years, we in line with the Government and the owners of the intellectualization systems engineering completion approval work successively on Shanghai jiushi Renaissance buildings, and telecommunications training building, Shanghai tongmao building, public building, Shanghai Pudong Development Bank building, no. 12, Bund Zhaofenghuanqiudasha, Zhao Feng world trade building, stock building BA system detection. On the BA system monitoring of power supply system, cooling system, air-conditioning system, lighting system, water supply and drainage systems, garage management systems for detection, real-time BA systems, reliability, security, ease of operation, easy maintenance, control, precision, and other important indicators as a system for evaluation. This work contributed to BA systems engineering contractors to the correction and improvement the quality of the project, not only achieved good social benefits, and the results of the work has been included in Shanghai in the intelligent construction series standards sent for approval.
1. about BA system detection methods
BA systems detection work first according to the project design document and contract technical file a complete view of the whole system's features and performance indicators. The detection system owner and the contractor must provide the main files a system selection, system scale capacity, control, process description, description of system functions and performance indicators, BA system chart, each subsystem control schematics, BA system equipment layout and wiring diagrams, and BA-system monitoring-related power distribution box electrical schematics, on-site equipment installation diagrams, DDC station and central management station/operator station monitoring program flowchart, central control room equipment layout, BA system supply contract and project contract, BA system construction quality inspection records and related engineering change orders, BA systems run record. On this basis, according to BA system acceptance criteria, develop a reasonable BA system detection scheme.
Testing is generally divided into three levels: central monitoring station, subsystem (DDC) and field devices (sensors, transmitters, implementing agencies, etc.) for feature detection.
1.1 central monitoring station inspection
Central monitoring station is on the premises each subsystem of DDC station data acquisition, refresh, control, and alarm central processing unit. Detection project are as follows:
In the central monitoring station observation Site status change, central monitoring station on-screen status data is constantly being refreshed and their response time;
Through central monitoring station control subordinate system simulation output or digital output, observation field enforcement agencies or if the object is valid and correctly, action action response returns a central monitoring station;
Human input in DDC station side manufacturing fault, the observation in the central monitoring station screen for alarm and fault data landing audible cues and their response time;
Artificially create a central monitoring station outage, regaining power transmission, the central monitoring station can automatically recover all monitoring and management capabilities;
Detecting whether a central monitoring station for operations personnel to give permissions to ensure the safety of BA system. Should illegal operations, ultra vires actions of rejection, to confirm;
Man-machine interface is finished, the central monitoring station screen to display the query, control equipment, observation equipment shipped processes is intuitive and easy to operate, to prove that the interface friendliness;
Detection of central monitoring station has the status of the device group self diagnosis function;
Detection of central monitoring station monitor and the printer is unable to report graphics and trends, to provide all or significant equipment running time, regional, and state information;
Detection system is provided for system design, applications, creation of graphics software tools;
Detection of central monitoring station is located in the control object parameters, and the scene is measured object parameters are consistent with the design of precision;
Detection of central monitoring station displays all devices running data is complete and accurate.
1.2 subsystem testing
Subsystem (DDC) is an independent run (slave) computer control system, on the scene a variety of sensors and transmitters of process signals in the ongoing collection, computing, control, alarm, etc., through the communications network to the (PC) central monitoring station database for central monitoring station for real time display, control, alarm, print, etc.
Testing subsystem project as follows:
Artificially create a central monitoring station downtime, the observation of various subsystems (DDC) works correctly;
Artificially create subsystem (DDC) lost power, the back transmission, subsystem can automatically recover lost power before setting the status of the operation;
Artificially create subsystem (DDC) and central monitoring station communication network outages, on-site equipment is up and running of automatically, and the central monitoring station for DDC station high line fault alarm signal login;
Testing subsystem (DDC) clock with central control station clock synchronized to the central monitoring station to various subsystems (DDC) monitor.
1.3 on-site equipment testing
Depending on the system design monitoring requirements, electrical signal into analog and digital content. Sensor and transmitter is the various physical (temperature, humidity, pressure,Flow, the electric valve to open degree, level, voltage, current, power, power factor, running, etc.) into the corresponding signal device. Executive agencies are based on the DDC output control signal for the work of the device. On-site equipment testing project as follows:
Check the field of sensors, transmitters, implementing agencies, DDC box installation specifications and reasonable, easy to maintain;
Detection of central monitoring station the displayed data, status and field readings, State;
Testing actuator action or action sequence is consistent with the design process;
When the parameter exceeds the allowable range, whether to generate alarm signals;
In the central monitoring station under the control of the executing agency actions properly.
1.4 feature detection
BA system for building equipment monitoring is usually completed by function and region. Therefore, the detection is based on a regional basis. With air conditioning and public lighting range, for example. Air conditioning zone is a place of work, rest, under the control of BA system, air-conditioning system should ensure a comfortable indoor temperature and good air quality. Detection of air conditioning and public lighting area are as follows:
Detection of central monitoring station on the air conditioning system control is carried out according to the schedule;
Testing air conditioning zone temperature, humidity and the central monitoring station display data match;
Detect whether indoor CO2 content meet the health standards;
Detection can, under time, control of public lighting area light switches and set lighting at night, in order to achieve the purpose of energy saving.
Through the above three levels and function, can real-time on BA systems, reliability, security, ease of operation, easy maintenance, equipment installation quality, control, precision made comprehensive evaluation, on the forth of problems. By rectification to be detected by the system to function correctly BA.
In BA systems engineering testing, always will find a lot of questions, after a certain time after rectification, most basic line with BA system project design documents and the contract technical features and specifications, system operation is good for certain energy saving effect. Detection of qualified BA system for building equipment monitoring, detection, control and warning of responding fast in real time; a high rate of Chinese operation interface, easy operation and maintenance, and have the device integrated management; system to manipulate staff permissions control strictly, level clear; systems work reliably; air conditioning zone control precision air conditioning system design requirements can be met.
In BA system testing usually there are some problems, mainly because there are several ways.
First, a small number of building professionals, HVAC and electrical professional designers at design time in the early expansion did not meet, as well as air conditioning tank room space is too small, it is difficult to walk on the maintain channel. Or new outlet location settings are not reasonable, outdoor air quality is not ideal.
Second, some BA designers on construction equipment are not familiar with, the integrity of the system does not understand that sensor location device error or even system lacks proper sensor and software tools.
Third, a few BA designers on air conditioning system operating and technology understanding not comprehensive, BA system for air conditioning system control mode is not reasonable, does not meet the goal of effective energy-saving.
Fourth, some construction personnel in the installation process, do not follow the specification, connection error, the sensor is installed in the wrong place, implementing agencies and device connection is not secure, DDC inside wiring mess, box and out of line without protection rubber gaskets, metal hose out la, to bring the system up and running.
Fifth, a property management company fails to run in BA system, make the necessary maintenance, leaving the original normal system ever fails.
3. concluding remarks
Intelligent building set BA systems are designed to provide comfort, health, safety, fast and quality services, energy and labor costs, the establishment of scientific management mode. To achieve the goal of building, needs engineering, construction and management of common efforts and hard work. With the development of science and technology, as a smart building technology pillars in building automation system technology will continue to progress, at the same time through the detection of BA systems will generally improve the quality of Chinese BA systems engineering.
【 Weak current College 】 industrial property management overview
1. analysis of industrial property management
At present, the property management industry is well known mainly embodied in the residential and Office services, for industrial property, dock, and other property related services and management is a process belonging to explore the whole industrial property section appears especially quiet and silent. For industrial property management standards are still in the planning since said that since "," stage, property management companies respective standards. Industrial property and residential, office buildings and other property features there were clear differences and different levels of difficulty, and for industrial property services, more just limited to daily floor cleaning and cosmetic security form. But because of the industrial property service and management models are still not able to form a same-sex and same knowledge, more industrial park are not yet open or that there is no consciousness forms professional property management. When everybody is will Davao residential, Office of property management market, industrial property into a vast empty grass fields, quietly waiting for the development and cultivation.
Second, the current specification service standards
Industrial property management of broad prospects are along with the social development and economic growth and rendered in people's eyes, but also makes us feel a lot of research and discussion of the merits, particularly how to specifically develop industrial property management service standards, how to develop a scientific and rational industrial property management fees, etc.
Any one of the industry to achieve healthy development, you will need to follow certain market laws and industry standards. 1 September 2003, the State of the property management Ordinance promulgated, property management to health, specifications, and sustained development of the legal track, but now the region Industry Department of management services standards are based on residential property, and other types of property for the reference implementation, which is not conducive to the development of industrial property management. Industrial property and residential property has many different point, practice performance in power supply, water supply, postal services and other sector does not include industrial community and residential quarter equal treatment, not to implement the policy of the end user fees; property management company is not an ordinary taxpayers, remit utilities cannot be issued for VAT invoice for the enterprise, leading enterprises (the owners) and contradictions of property management companies; on Science and Technology Park industrial plants for the payment of the public maintenance fund approach has not expressly, as later left the public service. Therefore, the research, development and introduction of a set of adapting industrial property management service standards and charges principle is the relationship between the industrial property owners and property management company on major issues of mutual interest, is the need for all levels of government authorities, experts, scholars and the industrial property management companies to explore and study of important topics.
III. industrial property management service requirements of content
Industrial property different stem residential, office buildings, its owner is a legal person, not a natural person. Natural persons seeking a comfortable living space, while the legal representative of a business, looking for a fit its production and management of public space. Therefore, property management service is to conform to these special requirements, can make targeted industrial property management.
Industrial property management service demand mainly in the basic services, extension services and community enterprise culture construction services three demands. Basic services in addition to residential property services, including direct guarantee normal production of electricity, water supply and drainage, elevators, fire, communication, information networks and other facilities, equipment maintenance; fire safety inspection and indoor censorship; to protect the enterprise normal production order for visitors to strict management; enterprise product, cargo security access to the management of all categories of vehicles; production waste removal, books journal and mail receiving and dispatching, and so on. Extension services including production needs to plants, Office renovation renovation; vehicles in the annual examination; business services, employee meals, as well as with municipal, health, transport, security, water supply, power supply, heat supply, streets and other administrations related transaction coordination, and management of fixed assets of the Park.
Above all this determines the industrial property management has its special mission, it is not only a kind of service and, more importantly, through the services to support the development of the service object, indirectly generates social benefits.
Fourth, how to effectively implement industrial property management services
For the majority of the owners, charterers to build an integrated service platform and create a free, secure, comfortable space for development. Industrial property management services, is also the final industrial property management.
So how do you effectively implement industrial property management?
For the first time as property management implementation, should take the initiative and the area of jurisdiction the administrative departments of the periodic summaries of enterprises and the difficulties encountered in the development, actively helping them with industry and commerce, taxation, public security, power, fire protection, environmental protection and other relevant departments to coordinate the resolution; to accept the Government delegate of functional departments, and business-related documents, announcements, regulations, management, law, communication to the enterprise in a timely manner.
Secondly as an extension of the property service, the Community introduced a Bank, post office, storage, transport, business centre, Conference Centre, products, service, catering, housekeeping, and other services, to provide in the Park enterprises, legal agent agent license, financing guarantee, equity participation, cooperation, planning, incubation, and other supporting services.
Once again expanded the functions of owners in the work of the Committee. And the owners ' Committee jointly organize entrepreneurs Association, enterprise development workshop, Conference, training sessions and other activities of safe production, strengthening of horizontal communication between enterprises and resource sharing.
Closing remarks
Property management of the "industrial age" as the national policy of favourable direction while getting closer, and for industrial property management mode and the service content of exploration will gradually get attention and focus, property management will have entered the market of industrial property, an "industrial age" of property management is coming, how can I become a kid of the times, how can I become an era of Kennedy, in the near future will be unveiled.
【 Weak current College 】 intelligent IC card system
0 introduction
The rapid development of information technology, profoundly changing people's mindset, lifestyle, lifestyle, changing the entire community.
1 origin of intelligent community
The intelligent construction the earliest produced in 1954, the United States Hart Ford city renovation of an old financial Tower, and on the building's air-conditioning, elevators, lighting, security, and other equipment used to monitor and control your computer, providing customers with voice communication, word processing, e-mail, and information and other information services, known as the world's first intelligent building. Subsequently, the rise of intelligent building boom. In China, the intelligent construction generally considered is the use of system integration, computer technology, communications technology, information technology and organic combination of architectural art, through the device of automatic monitoring, information resource management and on the consumer's information service and the optimal combination of architecture, the investment reasonable and appropriate to the information society require and have a safe, efficient, comfortable, convenient and flexible features of buildings.
Intelligent buildings generally consists of intelligent building (applies to government buildings and commercial buildings) and housing (applies to residential community). Intelligent community can graphically understood to intelligent building down, broke and dispersed, is IT technology to homes of penetration. Intelligent community and intelligent building, service objects and objectives vary, intelligent community in pursuit of a high-tech products for the residential areas provide a highly secure, comfortable and convenient services and 21st century network information. And the current increasing number, scale and more, features increasingly demanding large-scale residential district, there is an urgent need for the community of intelligent, high-tech means to establish a comfortable, safe and convenient for the main goals of smart Park, enhance the Park service goals and features that enhance people's quality of life.
2IC card introduction
IC card (smartCard) as an information storage and delivery media, in modern society are increasingly widely used. IC card or integrated circuit card, also often called a smart card (SmartCard). Will have storage, password checking, or encryption and other data processing capabilities of the integrated circuit chip embedded in the plastic substrate, will become the General common to the IC card.
According to the structure of IC card, that card is inserted in the IC and external circuit, such as IC cards can generally be divided into four categories: memory card, logic encryption card, CPU card or microprocessor cards, contactless IC card.
Because the IC card capacity, privacy is good (memory card), and magnetic cards, barcodes and other cards have a greater advantage than:
(1) a good read and write performance IC card is integrated circuit card, which eliminates the need for reciprocating machinery action to complete many times a machine a conversation between the card, the cards are applied in a more easy.
(2) good security in IC card uses the logic circuit design, IC manufacturing process and access control with password technology so that it can effectively prevent the card data unauthorized read and tampered with.
(3) large-capacity data storage capacity IC card has a large capacity of data storage capacity. Data in IC card is partition storage, in practice, different district store different content to different areas of read requests have different permissions. This is exactly what it is applied to the "one card". Several card storage capacity as shown in table 1.
3 intelligent IC card system
Intelligent IC card refers to one IC card can be in various community IC card subsystem use the subsystem of data, coexist in a single IC card, do not disturb each other, each subsystem also shared some of the data.
IC card possesses this function is and its structure. IC card generally four stores.
(1) open to the public (not private) store. Contains the public information, such as release identifier, the cardholder's account number, etc.
(2) external unreadable store. Storage is used for internal decision making, such as PIN values. The value is in the cards issued to individuals of written, users enter a correct PIN value, allows you to enter a new PIN values be modified, but in any case, are not allowed to be stored in the card's PIN values passed to the outside world. In the storage area can hold the key.
(3) secure store. Contains the book balance, allows the card to use the service type and limits, etc. Dangchika people to enter the correct PIN values that allow reading the store data, and applications written to the data.
(4) records of the district. Contains the details of each transaction is called a log that can be used by the query. In addition to the memory card, in other IC card also has logic circuits or microprocessor, provide safe and reliable service.
IC card application is wide, has a lot of new people to the area to be developed. Generally speaking, the intelligent IC card including IC card toll collection system, IC card parking lot management system management system, IC card entrance guard system, IC card system, property management company's internal systems, etc.
4-card system issues involved
4.1 "real-time full networking" or "offline" environmental problems
IC cards and large capacity storage capacity can make IC card application system into offline mode, important information such as passwords, amount, etc. are available on the card. Networking is the information in the database, IC card up to the identification of the role in the determination of the identity system to database query relevant information.
Important information on the IC card card, IC card has high reliability. The "real-time" system-wide networking, network security, reliability, toDemand is very high.
Can follow two methods, the combination of that information into the IC card is placed in the database. In system design, real-time full networking, i.e. on each business operation and host database communication, or by a certain time period information updates on the database.
4.2 blacklist feature
Blacklist is used to be a legitimate card system, but for various reasons and became the system of illegal card card list list. Legitimate card becomes illegal card may be the true owner of the card, this card is lost, or the card is operational system attackers.
IC card application system must have to provide the functionality of the blacklist, black list where a problem. There are two ways of storing blacklist:
Drop database in online mode, the blacklist can be placed in the database. Systems for each business operation and host database communication to view your current card is in the blacklist. This method is truly a blacklist, but undoubtedly also increased the burden on the network.
Into the lower computer this way will respond quickly, but also related to timely update of slave blacklist and lower computer capacity. In practice, the general use of the queue, the following bit machine store 1000 blacklist, when the 1001 a card loss reporting, blacklist of the first to be deleted. This obviously does not provide a truly complete blacklist functionality. As the system of long-term, blacklist will become longer and longer, this is a problem that needs to be considered. But in practice this may be feasible.
4.3 system security issues
Card system to have a high level of security, in real time or after the implementation of the safety of the settlement, minimize system operators and system users. From a certain perspective, system security issues directly related to the success of the system.
In General, the system might be following the attack in several ways:
(1) through the IC card. Scammers through theft or picking up the consumption of IC card, or forged out fake IC cards for consumption.
(2) illegal user terminals, users, or a managed card, communication lines, and other ways to enter the system; or the user beyond the permissions using the system, steal or modify data, the system for electronic fraud.
(3) through the network monitoring and modifying data. Due to the consumption point and Central Administration must pass to the network, which gives an intruder over a network system offers the potential for attack.
The main technical safety measures include: outline of key and password management; press different subsystem security needs of a variety of password protection: implementation supports micro-payment application of user consumption balance bottom account; the use of small consumption limit control risk management, etc. In practice, to a variety of security measures and to maximize the security of the system. The following describes encryption and password management.
Settlement Center database encryption management due to user's consumption record will be rolled up to the settlement Center database, for security reasons, some of the database involves funds table key field is encrypted for protection.
Transmission encryption management subsystem and clearing center all of the data exchanged is encrypted, including the subsystem to settlement center of consumer records and settlement centers to subsystems of blacklist.
User authentication on the system of regular user and system administrator for authentication to prevent unauthorized user access and use the system, so as to maximize the protection of the interests of users. Common user authentication by the various subsystems of the reader. The user is in the IC card encryption of user passwords, only the system card reader can read, even if an attacker has purchased the same reader cannot access the user's password.
5. concluding remarks
Intelligent community building's overall objective is in advanced computer technology, communications technology, control technology and IC card technology, based on the use of system integration, and gradually establish a communication with the Community internal households and households, household and community centres, household and external social interaction of multimedia information system for household provides a safe, comfortable, convenient and energy-saving, efficient environment for a family of intelligent, sustainable development, 21st century style of the intelligent community. To achieve these, the most important work is in a residential area, within the IC card system. Application of smart card technology for intelligent communities have a strong role in promoting, can significantly improve the living standards of the owners of the property management automation more mature.
The realization of the intelligent community will give developers and property management agencies have significant opportunities for development, to promote and enhance the development and property management, capture business opportunities, increased operating income, but also to establish and consolidate the company's brand, promote real estate sales. In short, from the social development of the situation, real estate agents and property companies on sale selling points and long-term development plans, must the construction and development of the intelligence community. Intelligent community building is a general trend.
【 Weak current College 】 intelligent community composition and level of
Intelligence community is to have a certain degree of intelligent housing community in General. Refers to the adoption of comprehensive configuration residential areas of functional subsystems, and cabling, the network will be a certain geographical area of housing, as well as the implementation of the various public facilities in the area of intelligent management of collection service to community needs, to provide safe, comfortable, convenient, energy saving and sustainable development of living environment. Intelligent community there are three important components that focus on the future of broadband data intense growth needs access transmission network to ensure domestic safety and automation capabilities of domestic intelligence network Terminal, as well as provide diversified information services and Park in the center of public property management.
Compare with smart buildings, smart community basic objective is to reach people and architectural and environmental symbiosis and common prosperity, more focused on meeting the household in security, living environment of comfort, convenience of community services and community management, has the effect of the proliferation of network communications, and other aspects of the implementation of and the demand for personalized (Ergonomics). How community features, gives the community a variety of features to meet the needs of the community, and in building intelligent format and has its own characteristics, this is a smart community should pursue.
From a general sense, intelligent community standards should meet the following requirements:
(1) to provide "local residents comfort, security, convenience" family living space, "people-oriented" and "energy saving is the first" and "environmental priority" principle is the focus of intelligent design; security and network traffic is a smart community's main features.
(2) has the information freeways family entrance, there is a fast, comprehensive information exchange;
(3) provides a rich and high-quality cultural and recreational life; including children's education, adult education, multi-level family and education services;
(4) provides for family health, tele-care services.
(5) community of property management to "efficient and thoughtful," as the goal, to a greater extent to meet the needs of local residents, service to the residents.
First, the intelligent community structure and function of
Community of intelligent system can be divided into domestic intelligence system, network wiring and management centre of the three-tier structure. Family inclusive family of intelligent control of all functions with new technology to streamline operations and convenience to users, improving the system of intelligent; the construction of network wiring, three are closely integrated into a unified intelligent network, and take fully into account the future demand for broadband; intelligent community integrated management center is a community of Intelligent Network Management Center, is the Community area and wide area networks connected to the channel.
To a certain extent, can be considered intelligent community = residential buildings of intelligent + community network. What grade of cabling systems and communication networks both hardware platform that is both a community building in one of the major investment, is also an important evaluation community. Especially on the community's forward-looking communication network required, otherwise it may cause a step failure will always lag behind embarrassing situation.
Intelligent Community system structure has the following characteristics: first use of advanced, standards-compliant technology and equipment; at the same time all of the system are distributed is structured, with scattered individual households in the terminal or device, through the network to a management or control center, the Center provides public information resources, or to individual households provide centralized security monitoring; and finally, all the intelligent system can be independent and in computer network based on centralized management.
Intelligence community's basic functional block diagram shown in figure a, including security, communication networks and three function block for property management and, through the integrated wiring subsystem will these three functional blocks and even become a system.
1. intelligent community has its integrated wiring subsystem.
Community intelligence system has three main platforms, intelligent home wiring intelligent community of the physical platform, computer network technology is the intelligence community's technology platform. Whereas the community choose the fieldbus is the intelligent community of application platforms. Control of residential equipment have CEBus, Profibus, LonWorks, and other types of BACnet. Intelligent system integration level and the selection of the closely related field bus, particularly affect community intelligence system integration capabilities of scalability.
Community achieve intelligent can have different programmes and approaches. One is the use of telecommunication lines, one is the use of cable TV networks, and then a bus system is the adoption of the community. Community bus system is the first establishment of the community's regional network, to connect several subsystems, and regional network with the public network.
Intelligent Community adopts comprehensive wiring design, should comply with smart home wiring standard TIA/EIA-570, used to implement the community building and the building of the backbone routing, as well as the floor of the residential wiring system. Wiring most star topology, unshielded twisted pair UTP joins.
2. essential communication network.
Intelligent community is the core network. In the ".COM" as the logo of the network society, broadband and intelligent is sure to become a community of equipment, live in the new community of users will soon be experience with broadband channel surf and use the telephone line of the huge difference. Currently, broadband access there are two ways, one is the comprehensive wiring, i.e. community dedicated to this LAN and LAN Internet is directly linked, on the family in the existing cable TV laying of fiber remake, is now a one-way channel cable TV cable into a two-way interactive (HFC). Using both alternative phone Internet access, can achieve online live broadcast TV shows, download, movies, and other "highly difficult moves", however due to a variety of reasons, the cable TV network is not likely to universal access to the InternetSo most of the new community have adopted the integrated distribution system to the laying of complimentary broadband Internet. But the future HFC and cabling, which will develop faster, it is difficult to predict.
Intelligent community of information communication service, should ensure that community residents with networking capabilities and a wide range of access service; this will bring the community to each House of the computers connected with wuyeguanlizhongxin implements new property management by ADSL high-speed Internet access, such as the community residents realize online education, online shopping, IP/TV, multimedia entertainment, online trading, online payment, VOD and Home Office, etc., but also can achieve on the remote control home appliances as well as a cartoon, video intercom, three table automatic meter reading, security/fire monitoring, parking management and other applications.
Since the IP protocol has an open and standard, you can use IP as a key technology of intelligent community. Open the IP to be a ubiquitous Protocol, IP-based Internet has been extended to every corner of the world, which has met the intelligent community population mobility and the needs of diversity. IP application through PSTN, ISDN, wireless networks, satellite networks and cable TV networks, etc. all kinds of transport into the wrong hands.
The popularity of the network will enable community digital information network project a reality. Community digital information network project is based on the global IP network established a financial intelligence information navigation, video on demand, multimedia information service, e-commerce and distance education, and other content as one of the integrated information system network. Users can use the system for fast, accurate and secure way to access and publish information in electronic transactions. On this basis, and gradually developed into a comprehensive information services and electronic commerce Center.
3. the community has intelligent control center, the goal is to ensure that the community of safe and effective management. Major subsystems (see Figure 2) are:
(1) the community and surrounding environment of security monitoring and safety precautions;
(2) family of alert prevention and community response network of alarm;
(3) the community parking lot management system;
(4) family "3" automatic CC transmission;
(5) the smooth flow of communications, protection of audio transmission.
4. community with property management subsystem, a card to complete the various fees.
Community digital information services market in the future will achieve substantial economies of scale. With good market platform to create a multifunctional, easy operation, low-cost integrated community network service system, the advanced Internet technology directly to such a popular and comprehensive service system, not only the mass from the high quality of the information to benefit directly from the network services, while also creating an efficient property of operation system and mode.
Second, the intelligence community's integrated management platform
Community connect various household and office network transmission media including telephone wiring system, cable TV distribution system (fiber-optic TV network), power distribution system and computer network cabling system (CAT 5 twisted-pair), the transmission medium should be the community's basic transmission media.
According to the location of the distribution function, it should be possible, as shown in Figure 3 of centralized management of applications. Park security management in addition to TV monitor system, electronic patrol, parking management and access management can use a safety management system. Household management can use a device to achieve the various objectives of intelligent management and, through the existing network transmission media (telephone, CATV, computer, network cabling, etc.) and central management system of interconnection, in order to reduce the investment and management costs.
3. residential community of intelligent classification standards
Currently, the implementation of the National Ministry of construction is organized in different regions, different types of residential community of intelligent technology demonstration projects. Residential community of intelligent grade will be based on its features and the corresponding investment, Ministry of construction in the national residential community of intelligent technology demonstration project outline "in the intelligent community demonstration project is divided into three levels, on the technical content of the following, as shown in table 1.
1. a popular residential area-the cost is approximately 5000 Yuan per household, the application of information technology to achieve the following functional requirements:
1) residential district to establish computer automation Center;
2) water, electricity, gas, heat, automatic measurement, charges;
3) residential district close to implement Security Automation monitoring and control;
4) residential fire, noxious gas leakage, the automatic alarm;
5) residential set emergency call system;
6) on the residential area of key equipment, facilities, centralized management, the implementation of the operational status of the remote control.
2. Advanced residential community — cost nearly $ 30 million per household application of information technology and network technology to realize the following functional requirements:
1) implementation of the universal system of all functional requirements;
2) residential and urban regional networking, exchange of information and resource sharing;
3) households through network Terminal realization of medical, cultural, commercial and other public services and fees automatically clearing (or have the implementation conditions).
4) households by family PC reading e-books and publications.
3. leading residential community — cost about residential investment of 1 ~ 2 (, application of information technology, network technology, and information integration technology to realize the following functional requirements:
1) achieving the full functionality requires advanced;R>
2) realization residential development and construction technology, applied HI-CIMS residential community development life-cycle of the modern information integration system to improve the quality, effective management, the goal of improving the environment.
As the IT technology and smart Park Home Automation development combined with the intelligent community building and Park Service functionality objectives is also getting higher and higher. And intelligent community of intelligent system is a computer network and numerous high-tech product combination of products, not only on the residential construction hardware environment improved and contains a reference to the park management and community services for the improvement of the software content. 21st century information age smart Park, you should park residents "safe living environment, a warm community service, and convenient information contact"